DC to DC TRANSDUCER ISOLATING AMPLIFIER

Datasheet (Adobe Acrobat Format)

Features:

Applications:

The transducer converts a DC voltage or current into a load independent DC current or voltage signal which may be used to drive a number of remotely installed instruments.

This transducer has been designed with a fast response for use in feedback circuits of motor drives. A lower ripple - slower response version for data loggers can be supplied.

The output is protected against over-voltages due to surges or accidental contact with insulation testers or the mains supply.

The auxiliary voltage supply is user selectable to either 110V or 220V AC by means of a jumper. A 24V or 110V DC version is also available.

MODE OF OPERATION

The input signal is fed through a passive network (1) to scale it to a suitable value for the isolating amplifier (2). This amplifier has optically isolated input and output stages to give the necessary galvanic separation. The output amplifier (3) provides either a load independent current signal (with maximum burden) or a load independent voltage signal (with minimum burden). The auxiliary voltage is transformed in (5) and (6) and then rectified and smoothed in (4) and (7), thus providing each galvanically separate section of the transducer with its own auxiliary supply. The DC supply version has an inverter before the transformer section.

Block Diagram

CONNECTION DIAGRAM


DIN A Housing


LDG10 Housing

 

TECHNICAL DATA

1. Input  
Input quantity: Any value from 10µA to 10A or from 10mV to 600V DC (bipolar)
Input burden: 1V for mA ranges 0.1V for A ranges 10kW/V for V ranges
Overload in terms of rated input: 1.5x indefinitely
10x 0.5 seconds
2. Output  
Characteristic: A or B or C or D or E or F
Output quantity: Current or voltage signal
Current standard values: 1mA, 5mA, 20mA unipolar or bipolar
Maximum load: 5k, 2.5k, 750 Ohm.
Voltage standard values: 1V, 5V, 10V unipolar or bipolar
Minimum load: 500 Ohm
Maximum output voltage: 32V DC
Maximum output current: 1.25x rated (typical)
2.0x rated (maximum)
Ripple: 0.5% standard
Response time: 0.2ms standard
3. Auxiliary power supply  
Voltage:  
AC: 110 or 220V ( User selectable ) 50Hz ±20%
DC: 24V or 110V DC
Burden: <3.5VA at rated output
4. Accuracy  
Error limit at rated conditions: ±0.5% of range
Linearity error: 0.25%
Long term drift: 0.25%
Temperature shift: 400ppm/°C
Variation with auxiliary supply: 0.05% for ±20% variation
5. Protection  
Impulse test between isolated sets of terminals: 4kV (0.5J 1.2/50 wave) IEC standard
Voltage withstand rating between sets of terminals: 2.5kV 50Hz AC for 1 minute
Power voltage across output: 220V 50Hz indefinitely
Surge across output terminals: 5kV 25J
1kV 4J
6. Physical constraints  
Working temperature: -25 to 13 to 33 to 55°C
Storage temperature: -55 to 75°C (above dewpoint)
Relative humidity: 80%
Variation due to external magnetic field (worst case): 0.05% at 400A/m 50Hz
Position: Surface mounting in any position indoors.
7. Enclosure Type DIN A:
Type LDG6: